INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE.
Electric Fireplace
Models: TBREF36,
TBREF36NH
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, AN ELECTRICAL
SHOCK OR FIRE MAY RESULT,
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY
SERVICE MUST BE
PERFORMED BY A QUALIFIED
SERVICE AGENCY.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
Homeowner's Installation &
Operating Manual
C
US
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
10007572 5/05 Rev. 1
TBREF Electric Fireplace
Installation Instructions
14. Do not strike the fireplace glass.
15. Always use a certified electrician for installation.
General Information
1. Read all instructions before using this appliance.
16. Disconnect all power coming to fireplace at main
service panel before performing any cleaning or
maintenance.
17. Do not install this fireplace on carpet or vinyl floors,
as discoloration may occur.
2. This appliance is hot when in use. To avoid burns, do
not let bare skin touch hot surfaces. If provided, use
handles when moving this appliance. Keep combus-
tible materials, such as furniture, pillows, bedding,
papers, clothes and curtains at least
18. SAVE THESE INSTRUCTIONS.
3 feet (1 m) from the front of this appliance.
CAUTION: Extreme caution is necessary
when any heater is used by or near chil-
dren or invalids, and whenever the heater
is left operating and unattended.
Wiring
Ensure the power conversion/switch (if
equipped) is in the proper position for re-
quired supply voltage prior to connecting
the unit to power supply.
3. Do not operate any heater if the appliance malfunc-
tions, or if it has been dropped or damaged in any
manner.
4. Any repairs to this fireplace should be carried out by
a qualified service person.
5. Under no circumstances should this fireplace be
modified. Parts having to be removed for servicing
must be replaced prior to operating this fireplace
again.
Do not use this fireplace if any part of it
has been under water. Immediately call a
qualified service technician to inspect the
fireplace and replace any part of the elec-
trical system that has been under water.
A qualified electrician must perform any
electrical wiring of this appliance. This wir-
ing must be done in accordance with local
codes, and/or in Canada, with the current
CSA C22.1 Canadian Electrical code; for
U.S.A. installation, National Electrical Code
ANSI/NFPA No. 70.
6. Do not use outdoors.
7. This heater is not intended for use in bathrooms,
laundry areas and similar indoor locations. Never
locate this appliance where it may fall into a bathtub
or other water container.
8. This appliance, when installed, must be electrically
grounded in accordance with local codes, or, in the
absence of local codes, with the current CSA C22.1
Canadian Electrical Code; for U.S.A. installations,
follow local codes and the National Electrical Code,
ANSI/NFPA NO. 70.
NOTES: The unit is shipped from the factory config-
ured for 120 Volt operation.
Ensure the power conversion switch is in the
proper position for the required supply voltage.
All wiring must be completed prior to installing the
unit.
9. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening, as this may cause an
electric shock or fire, or damage the appliance.
10. To prevent a possible fire, do not block air intake or
exhaust in any manner. Do not use on soft surfaces
(e.g., beds) where openings may become blocked.
11. This appliance has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline, paint or
flammable liquids are used or stored. This fireplace
should not be used as a drying rack for clothing, nor
should Christmas stockings or decorations be hung
in the area of it.
12. Use this appliance only as described in this manual.
Any other use not recommended by the manufactur-
er may cause fire, electric shock or injury to persons.
Electrical Connection
1. Loosen the screws securing junction box cover.
2. Remove knockouts in the box cover to use a cable
clamp.
3. Place the unit in position in the opening. Level it with
shims if necessary, and attach the unit to the frame
using the nailing flanges provided.
4. The unit is factory wired for 120 Volt power supply.
If 208/240 Volt operation is required, flip the switch
located on junction box and reconfigure the wiring
as covered on page 7. Wires L1, L2, N, and G are
located inside the junction box.
5. Wire a dedicated, properly fused, 20 Amp rated
circuit for appropriate voltage (120 or 208/240).
6. Place all connectors inside junction box and replace
the cover to ensure connections are tight.
13. Do not burn wood or other materials in this fireplace.
10007572
3
TBREF Electric Fireplace
Fireplace Dimensions
Rough
Opening
Depth
H
M
1/2" (13mm)
5/8" (16mm)
Recessed
L
G
Nailing Flange
O
K Rough Opening Width
M
5/8" (16mm)
Rough
Opening
Height
N
E
D
J
B
F
C
3���"
(95mm)
E
7�����"
(192mm)
2�����"
A
(60mm)
Fig. 1 Fireplace specifications and framing dimensions.
Ref.
A
TBREF36/TBREF36NH
40"
36"
(1016mm)
B
(914mm)
(914mm)
(533mm)
(191mm)
(502mm)
(356mm)
(698mm)
C
36"
D
21"
E
7¹⁄₂"
19³⁄₄"
14"
F
G
H
27¹⁄₂"
Framing Dimensions
J
K
L
36¹⁄₂"
41"
(927mm)
(1041mm)
(356mm)
(953mm)
1372mm)
(686mm)
14"
M
N
O
37¹⁄₂"
54"
27"
Electrical Specifications
Voltage:
Total Amps:
120 Volt
120 Volt (NH)
2 Amps
240 Volt
13 Amps
12.9 Amps
3100 Watts
2855 Watts
Total Watts:
1550 Watts
1455 Watts
240 Watts
N/A
Heater Rating:
4
10007572
TBREF Electric Fireplace
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For correct mounting height and width, refer to Figure
2a and 2b.
J
I
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
H
Black
Surround
Face
G
F
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
Mantel Leg
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat-resistant to prevent dis-
coloration.
CFM164a
K
L
M
N
Side of Combustion
Chamber
O
Mantel Clearances
V
W
X
Y
Wall
Z
CFM170
Mantel
Leg Depth
Mantel Leg from Side
of Comb. Opening
Ref.
Ref.
A
B
C
D
E
F
G
H
I
14" (356mm)
12" (305mm)
10" (254mm)
8" (203mm)
1¹⁄₂" (38mm)
K
L
M
N
O
14" (356mm)
12" (305mm)
10" (254mm)
8" (203mm)
1¹⁄₂" (38mm)
J
Fig. 2b Combustible mantel leg minimum installation.
Top of Combustion Chamber
Framing
CFM146b
1. Choose fireplace location.
2. Place fireplace into position.
Mantel Shelf
Mantel from Top
Ref.
Ref.
3. Frame in the fireplace with a header across the top.
It is important to allow for finished face when setting
the depth of the frame.
Depth
of Comb. Chamber
V
W
X
Y
Z
14" (356mm)
12" (305mm)
10" (254mm)
8" (203mm)
1¹⁄₂" (38mm)
A
B
C
D
E
25" (635mm)
23" (584mm)
21" (533mm)
19" (483mm)
15" (381mm)
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 3.
Fig. 2a Combustible mantel minimum installation.
10007572
5
TBREF Electric Fireplace
Hearth
A hearth is not mandatory; however, for aesthetic pur-
poses, we recommend use of a noncombustible hearth
that does not obstruct the air openings.
Cold Climate Installation: To conform to
applicable insulation codes, it is manda-
tory the outer walls be insulated when
installing this unit against a non-insulated
exterior wall or chase.
Nail
side-nailing
flange
Cabinet Installations
FP549
Cabinets are available from your dealer which allow
fast, convenient installation of your fireplace against
existing walls.
Fig. 3 Adjustable drywall strip (nailing flange).
Finishing
Main Power Wall Switch Wiring
CAUTION: All joints between the finished
wall and the appliance surround (top and
sides) may be sealed only with noncom-
bustible material. Only noncombustible
material can be applied as facing to
the appliance surround (the black painted
face).
To reduce the risk of fire, electrical shock,
and personal injury, before attempting
maintenance or service, disconnect all
power to the fireplace
at the main service panel.
120 Volt Wall Switch Wiring Installation
A qualified electrician must perform any
electrical wiring of this appliance. For Ca-
nadian installations, wiring must be done
in accordance with local codes, and/or
the current CSA C22.1 Canadian Electrical
Code. For U.S.A. installations, wiring must
be done in accordance with the National
Electrical Code ANSI/NFPA No. 70.
When finishing the appliance, never obstruct or
modify the air inlet/outlet grilles in any manner.
NOTE:Finish the wall with the material of
your choice. Refer to Figures 2a and 2b for specific
clearances when installing a combustible mantel or
other combustible projection.
Locating your Electric Fireplace
NOTE: For 120 Volt installations, use a
single-pole, single-throw, 20 Amp-rated wall switch.
Your new fireplace may be installed into an existing
masonry or zero-clearance fireplace. It may also be in-
stalled using a prefabricated cabinet available from your
dealer, or be built into a wall.
Wiring of the wall switch must be completed prior
to installing the unit.
Connect the wall-mounted switch to the fireplace by
running grounded 2-conductor wire (Min.14 AWG) to
the switch from the junction box on the side of the unit.
When choosing a location for your new fireplace, en-
sure that the general instructions are followed. Also, for
best effect, install the fireplace out of direct sunlight.
1. Locate the voltage selection switch under the logset
on the left front corner of the unit.
Clearance to Combustibles
2. Ensure the switch is in the 120 Volt position.
3. Loosen the screws securing the junction box cover,
and remove the cover.
Sides ......................................................... 0" (0 mm)
Floor.......................................................... 0" (0 mm)
Top ........................................................... 0" (0 mm)
4. Remove knockouts in the box cover to use a cable
clamp.
5. Pull out two (2) wires: black and white.
6. Connect the hot wire (black) from the wall switch to
the L1 (black) wire on the unit, and the other wire
from the wall switch to the L1 (black) wire on the
power supply.
7. Connect the white wire from the unit to the neutral
(white) wire on the power supply.
6
10007572
TBREF Electric Fireplace
120/240 Volt Wall-Mounted
8. Connect the ground wire from the wall switch to the
wire grouping from the power supply and the ground
stud in the junction box.
Thermostat Wiring
9. Make sure the red wire (L2) in the junction box has a
closed end splice or a wire nut properly applied.
10.Ensure all connections are tight. Insert all wiring
inside the junction box and secure the cover.
Before attempting maintenance or ser-
vice—to reduce risk of fire, electrical
shock and personal injury—disconnect all
power to the fireplace at the main service
panel.
240 Volt Wall Switch Wiring Installation
NOTE: Wiring of the wall thermostat must be com-
pleted prior to the installation of the unit.
A qualified electrician must perform any
electrical wiring of this appliance. For
Canadian installation, wiring must be done
in accordance with local codes, and/or
the current CSA C22.1 Canadian Electrical
Code. For U.S.A. installation, wiring must
be done in accordance with the National
Electrical Code ANSI/NFPA No. 70.
Use a single pole thermostat rated for 120/240 Volt
operation.
When installing the wall thermostat, make sure to
turn the heater control inside fireplace all the way
clockwise to the highest set point temperature.
Connect the wall-mounted thermostat to the fireplace
by running a grounded 2-conductor wire (min. 14 AWG)
to the thermostat from the junction box on the side of
the unit.
NOTE: For 240 Volt installations, use a double-
pole, single-throw, 20 Amp, 240V rated wall switch.
Wiring of the wall switch must be completed prior
to installing the unit.
1. Loosen the screws securing the junction box cover
and remove the cover.
2. Remove knockouts in the box cover to use a cable
clamp.
3. Pull out the two (2) brown wires with the closed end
splice at the end.
4. Cut off the closed end splice, separate the two wires,
and strip approximately 5/8" (15mm).
5. Connect one (1) wire from the thermostat to one (1)
of the brown wires; connect the other wire from the
thermostat to the other brown wire.
Connect the wall-mounted switch to the fireplace by
running grounded 3-conductor wire (MIN. 14 AWG) to
the switch from the junction box on the side of the unit.
1. Locate the voltage selection switch under the logset
on the left front corner of the unit.
2. Move the switch from the 120 Volt to the 240 Volt
position.
3. Loosen the screws securing the junction box cover,
and remove the cover.
6. Connect the ground wire from the wall thermostat to
the power supply wire group and the ground stud in
the junction box.
7. Ensure all connections are tight. Insert all wiring into
the junction box and secure the cover.
4. Remove knockouts in the box cover to use a cable
clamp.
5. Pull out three (3) wires: black, red, and white.
6. Connect one (1) wire (black) from the wall switch to
the L1 (black) wire on the unit, and the other wire
from the wall switch to the L1 (black) wire on the
power supply.
Installation Cautions
7. Connect one (1) of the wires from the wall switch to
the L2 (red) wire on the unit, and the other wire from
the wall switch to the L2 (red) wire on the power sup-
ply.
8. Connect the white wire from the unit to the neutral
(white) wire on the power supply.
9. Connect the ground wire from the wall switch to the
wire grouping from the power supply and ground
stud in the junction box.
10. Ensure all connections are tight. Insert all wiring
inside the junction box and secure the cover.
Make sure the power is turned OFF before
proceeding.
If repairing or replacing any electrical com-
ponent or wiring, the original wire routing,
color coding and securing locations must
be followed.
Any electrical repairs or rwiring of thisunit
should be carried out by a licensed electri-
cian in accordance with natioinal and local
codes.
10007572
7
TBREF Electric Fireplace
120 Volt Unit Installation
5. Pull out three (3) wires: black, red, and white.
6. The unit is shipped from factory with a closed end
splice on the red wire. Cut off this splice and strip
approximately 5/8" (15mm) wire sheathing.
1. Locate the switch under the logset on the left front
corner of the unit.
7. Connect the black wire from the unit to the L1
(black) from the power supply. Connect the red wire
from the unit to the L2 (red) from the power supply.
Connect the white wire from the unit to the neutral
(white) from the power supply.
NOTE: Wiring must be connected to a 20 Amp
dedicated circuit breaker or fuse in the electrical
panel of the dwelling.
2. Check the voltage selection switch position to ensure
it is in the 120 Volt position.
3. Loosen the screws securing the junction box cover
and remove the cover.
4. Remove knockouts in the box cover to use the cable
clamp.
5. Pull out two (2) wires: black and white.
6. Connect the black wire from the unit to the L1 (black)
from the power supply. Connect the white wire from
the unit to the neutral (white) from the power supply.
NOTE: Wiring must be connected to a 20 Amp
dedicated circuit breaker or fuse in the electrical
panel of the dwelling.
7. Connect the ground wire from the power supply to
ground stud in the junction box.
8. Make sure the red wire (L2) in the junction box has a
closed end splice or a wire nut properly applied.
8. Connect the ground wire from the power supply to
ground stud in the junction box.
9. When the unit has been configured for the appropri-
ate power supply voltage, ensure all connections
are tight. Insert all wiring inside the junction box and
secure the cover.
10. Turn the power to the unit on at the breaker/fuse
panel. Place the unit into operation and check to
make sure the whole system is operating properly.
Resetting the
Temperature Cutout Switch
9. When the unit has been configured for the appropri-
ate power supply voltage, ensure all connections
are tight. Insert all wiring inside the junction box and
secure the cover.
10. Turn the power to the unit on at the breaker/fuse
panel. Place the unit into operation and check to
make sure the whole system is operating properly.
To reduce the risk of fire, electrical shock,
and personal injury, before attempting
maintenance or service, disconnect all
power to the fireplace at the main service
panel.
120 Volt (NH) Unit Installation
NOTE:The heater on this fireplace is protected with
a safety limit device to prevent overheating. Should
the heater overheat, an automatic cutout turns the
heater OFF; it will not come back ON without being
manually reset.
1. Loosen the screws securing the junction box cover
and remove the cover.
2. Remove knockouts in the box cover to use the cable
clamp.
The safety limit device is located in a cutout at the right
front top corner by the cover fan/heater. To reset the
switch, insert a small flat screwdriver into this cutout
and push the reset button on the safety limit device.
3. Pull out two (2) wires: black and white.
4. Connect the black wire from the unit to the L1 (black)
from the power supply. Connect the white wire form
the unit to the neutral (white) form the power supply.
5. Connect the ground wire from the power supply to
the ground stud in the junction box.
6. Ensure all connections are tight. Insert all wiring
inside the junction box and secure the cover.
Safety Limit Device
7. Turn the power to the unit on at the breaker/fuse
panel. Place the unit into operation and check to
make sure the system is operating properly.
Cover Fan/
Heater
240 Volt Unit Installation
Small Flat Screwdriver
1. Locate the voltage selection switch under the logset
on the left front corner of the unit.
FP1452
2. Check the switch position to ensure it is in the
240 Volt position.
Fig. 4 Reset the switch with a small flat screwdriver.
3. Loosen the screws securing the junction box cover
and remove the cover.
4. Remove knockouts in the box cover to use the cable
clamp.
8
10007572
TBREF Electric Fireplace
Screen Kit Installation
(Clip)
1. Remove the plastic bag from each screen.
2. Remove the four (4) metal clips, two (2) for each
side of the fireplace opening.
3. Slide screen panels against sides of the fireplace
opening.
4. Align each metal clip with the hole it was removed
from, while at the same time, hooking the clip
through the last wire of the screen. Snap clips into
place. (Fig. 5)
5. Pull screens back and forth to ensure they work
freely.
FP1041
Fig. 5 Clip installation.
Service Instructions
To reduce the risk of fire, electrical shock
or personal injury, disconnect all power
coming to the fireplace at the main service
panel before attempting any maintenance
or cleaning.
4. Remove the four (4) screws securing the ember bed
in position. Two (2) screws are located on either side
of the ember bed near the front and rear.
5. Examine the bulbs to determine which one(s) need
to be replaced (if you are not going to replace all).
7. Install new light bulb(s) by screwing in while holding
the socket.
8. Reinstall the ember bed, log set, glass door, and
steel curtain.
Maintenance of Motor
The motors used on the fan and the drum assemblies
are prelubricated for extended bearing life, and require
no further lubrication. However, periodic cleaning/vacu-
uming of the fan/heater is recommended.
Cleaning Trim
Replacing Light Bulbs
Clean the trim using a soft cloth you have slightly damp-
ened with lemon oil; then buff with a clean soft cloth.
This fireplace uses four (4) clear, 120 Volt, 60 Watt,
E-12 socket base (small base, chandelier candle-type)
light bulbs. These lights are located under the ember
bed of the unit.
NOTE:You can obtain lemon oil at super-markets
and hardware stores. Do not use commercially
made brass polish or household cleaners, as these
products will damage the trim.
Do not exceed 60 Watts per bulb. Use of
higher-rated bulbs may result in fire, caus-
ing property damage, personal injury, or
loss of life.
NOTE: For the sake of convenience, you may wish
to consider replacing all the light bulbs if one of
them burns out.
1. Turn OFF the power to the unit at the main service
panel.
2. If the fireplace has been operating, allow it to cool.
3. Open glass (if applicable); open steel curtain.
10007572
9
TBREF Electric Fireplace
Electrical Wiring Diagram with Heater and Integral Remote Control
G
1 WHITE
REAR
1
FRONT
11 RED
4
2 WHITE
16 BLACK
13 RED
22 WHITE
16 BLACK
2
15
4 BLACK
L1
FAN/HEATER
MOTOR
15 BLACK
5
T'S
1
3
6
2
6 RED
3
14 BROWN
4
5
14 BROWN
21 WHITE
12
16
COIL
24 WHITE
19 WHITE
3
1b
1
2b
2
9
7
FLAME
MOTOR
9 BLACK
2a
1a
13
8 BLACK
18 WHITE
3 BLACK
10 BLACK
BLACK
WHITE
L2
N
25 RED
23 WHITE
7 BLACK
BLACK
17 WHITE
WHITE
17
11
10
IN
N
OUT IN OUT
L
L
N
Component Identification
1. Heater Element
2. Limit Control, 175/20 DIF
3. Relay Switching, 120V, 50/60Hz
4. Fan/Heater Motor
5. Thermostat
6. Switch, Rocker
7. Switch
9. Light Bulb
10. Light Socket w/Wiring Assembly
11. Cable Tie Nylon 6"-1¹⁄₈" Black
12. Bushing Snap, Split 1"
13. Closed End Splice 2/18 Ga. Wire
14. CFM Wire Req'd BREF36
15. Sensor, 230°F Manual Reset
8. Flame Motor
16. Closed End Splice 3/4" 18GA Wire
17. Receiver
FP1541
Fig. 6 Wiring diagram for models with heat.
10
10007572
TBREF Electric Fireplace
Electrical Wiring Diagram without Heater and Integral Remote Control
G
2
7 WHITE
MOTOR
FLAME
3
1
3
2
N
8 WHITE
4 BLACK
O
I
1
3 BLACK
6 WHITE
L1
1 BLACK
BLACK
WHITE
BLACK
WHITE
2 BLACK
5 WHITE
4
5
CFM Component Identification
1. Switch
2. Flame Motor
3. Light Bulb
4. Light Socket w/Wiring Assembly
5. Cable Tie Nylon 6" - 1¹⁄₈" Black
6. CFM Wire req'd
FP1540
Fig. 7 Wiring diagram for models without heat.
10007572
11
TBREF Electric Fireplace
Operating Instructions
Control Panel
The control compartment is located inside the fireplace
behind the steel curtain near the left front corner. To ac-
cess the controls, simply slide the steel curtain open.
1. ON/OFF Switch
1. ON/OFF Switch
The ON/OFF switch is for supplying power to light ef-
fects of the fireplace. This switch is normally illuminated
to indicate that there is electrical power to the unit.
2. Heater Control
The heater control acts to turn the heater ON and OFF,
as well as setting the comfort level in the room.
2. Heater Control
FP1451
Turn the knob clockwise from the "OFF" position to
place the heater into operation. The further the knob is
rotated clockwise, the higher the set point temperature.
Fig. 8 Control panel.
NOTE: The device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
Turn the knob counterclockwise to lower the set point
temperature. Turn it all the way counterclockwise to turn
the heater function OFF.
1. This device may not cause harmful interference,
and
2. This device must accept any interference re-
ceived, including interference that my cause
undesired operation.
12
10007572
TBREF Electric Fireplace
TBREF36, TBREF36NH
1
2
3
4
7
5
6
8
9
15
11
13
14
16
12
��
20
17
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products
at any time, without notice.
TBREF36, TBREF36NH Electric Fireplace
10007572
13
TBREF Electric Fireplace
TBREF36, TBREF36NH Electric Fireplace (continued)
Ref. Description
TBREF36
10007423
10004584
10004262
10001393
10002987
10004695
10004720
10001639
10007443
10007430
10007461
10003350
10007434
10007447
10006453
10001172
10008487
10008487
10006382
7554338
TBREF36NH
10007423
--
1. Log Set Complete
2. Heater Element
3. Motor, AC, w/Terminals
4. Rocker Switch (Illuminated)
5. Thermostat - Heater Control
6. Fan w/Bracket Assembly
7. Sensor, 230°F Manual Reset
8. Knob - Heater Controls
9. Plate Control Assembly
10. Screen Tinted Plastic (not shown)
11. Ember Lava Rock
10004262
10001393
--
--
--
--
10007608
10007430
10007461
10003350
10007434
10007447
10006453
--
12. Flame Generator Assembly
13. Support Plate
14. Plate Log Support Assembly
15. Socket Light Bulb Lower Assembly
16. Limit Control, 175/20 DIF
17. Transmitter
--
18. Receiver
--
19. CFM Wire Req'd (not shown)
20. Screen Assembly
10007639
7554338
10007433
7554239
7512135
21. Screen Rod
10007433
7554239
22. One Piece Screen Pull (2 per Fireplace)
23. Cable Clip (4 per Fireplace)
7512135
NOTE: Items 17 and 18 (Transmitter and Receiver) must be replaced as a set.
Accessories
The following accessories for these appliances are
available from your local CFM Specialty Home Products
distributor.
See your CFM Specialty Home Products distributor or
dealer for other finishing options, such as marble and
mantels that are available in a wide selection of styles.
NOTE: Each accessory comes with a separate in-
stallation instruction for mounting to the particular
appliance. Be sure to read each instruction thor-
oughly before installing.
Accessory
Description
Model Number
Thermostat
Power Cord
Refractory Kit
Wall Thermostat, electric fireplace
EBWT
10003095
Refractory panels give the appliance
a realistic brick look
BREF36RK
Bi-fold Glass Doors Glass doors enhance the viewing area Brushed Brass - 36GDKBB
of the fire
Black - 36GDKBK
Polished Brass - 36GDKDP
Pewter - 36GDKS
14
10007572
1 YEAR WARRANTY
For TEMCO FIREPLACE PRODUCTS Electric Fireplaces
BASIC WARRANTY:
GARANTIE DE BASE:
CFM Specialty Home Products (hereinafter referred to col-
lectively as the "Company") warrants that your new Majestic
Fireplaces® fireplace is free from manufacturing and material
defects for a period of one year from date of installation, sub-
ject to the following conditions and limitations.
CFM Specialty Home Products (aux présentes nommée la
"Société") garantit votre nouveau foyer électrique Majestic
Fireplaces® contre tous défauts de fabrication et de matières
premières pour une période d'un an à compter de la date
d'installation, sujet aux conditions et limitations suivantes.
1. Le foyer electrique doit être installé par un entrepreneur de
service autorisé et compétent. Il doit être installé et utilisé en
tout temps selon les instructions d'installation et de fonctionne-
ment fournies avec le produit. Toute altération, abus volon-
taire, accident ou mauvais usage du produit annulera cette
garantie.
2. Cette garantie n'est pas transférable et est offerte à l'acheteur
au détail d'origine, à condition que l'achat soit effectué par
l'entremise d'un détaillant autorisé de la Société.
3. Cette garantie est limitée à la réparation ou au remplace-
ment de(des) pièce(s) trouvée(s) défectueuse(s) en matières
premières ou main-d'oeuvre, à condition que lesdites pièces ai-
ent été sujettes aux conditions normales d'usage et de service,
après que ledit défaut a été confirmé par une inspection par la
Société.
1. This electric fireplace must be installed and operated at all
times in accordance with the Installation and Operating instruc-
tions furnished with the product. Any alteration, willful abuse,
accident, or misuse of the product shall nullify this war-
ranty.
2. This warranty is non-transferrable, and is made to the original
owner, provided that the purchase was made through an au-
thorized supplier of the Company.
3. This warranty is limited to the repair or replacement of part(s)
found to be defective in material or workmanship, provided that
such part(s) have been subjected to normal conditions of use
and service, after said defect is confirmed by the Company's
inspection.
4. This warranty does not cover the lightbulb(s) included with
the fireplace
.
4. Cette Garantie ne couvre pas les ampoules inclus dans le
foyer électrique.
5. The Company may, at its discretion, fully discharge all obliga-
tions with respect to this warranty by refunding the wholesale
price of the defective part(s).
6. Any installation, labour, construction, transportation, or other
related costs/expenses arising from defective part(s), repair,
replacement, or otherwise of same, will not be covered by this
warranty, nor shall the Company assume responsibility for
same. Further, the Company will not be responsible for any
incidental, indirect, or consequential damages, except as pro-
vided by law.
7. All other warranties - expressed or implied - with respect to
the product, its components and accessories, or any obliga-
tions/liabilities on the part of the Company are hereby expressly
excluded.
8. The Company neither assumes, nor authorizes any third party
to assume, on its behalf, any other liabilities with respect to the
sale of this Majestic Fireplaces product.
5. La Société peut, à sa discrétion, se décharger entièrement de
toutes obligations se rapportant à cette garantie en rembour-
sant le prix de gros de la(des) pièce(s) défectueuse(s).
6. Tous les frais/dépenses d'installation, de main-d'oeuvre, de con-
struction, de transport ou autres causés par une (des) pièce(s)
défectueuse(s), une réparation, un remplacement ou autre, ne
seront pas couverts sous cette garantie, et la Société n'assume
aucune responsabilité pour ceux-ci. De plus, la Société ne
pourra être tenue responsable pour tous dommages fortuits ou
indirects sauf la ou prévu par la loi.
7. Toutes autres garanties, exprimées ou sous-entendues, en ce
qui a trait au produit, ses composants et accessiores, ou toutes
obligations/responsabilités de la part de la Société sont aux
présentes expressment excluses.
8. La Société n'assume et n'autorise personne à assumer, en son
nom, toutes responsabilités en ce qui a trait à la vente de ce
9. The warranties as outlined within this document do not apply to
non CFM Specialty Home Products accessories used in conjunc-
tion with the installation of this product.
produit Majestic Fireplaces
.
9. Les garanties, telles que décrites dans ce document, ne
s'appliquent accessoires non CFM Specialty Home Products
utilisés conjointement pour l'installation de ce produit.
10. Cette garantie est nulle si:
This warranty is void if:
a) The fireplace has been operated in atmospheres contami-
nated by chlorine, fluorine or other damaging chemicals.
b) The fireplace is subjected to prolonged periods of damp-
ness or condensation.
c) Any alteration, willful abuse, accident, or misuse of the
product.
a) Le foyer a été utilisé dans une atmosphère contaminée
par du chlore, du fluor ou tous autres produits chimiques.
b) Le foyer est assujetti à de longues périodes d'humidité ou
de condensation.
c) Toute altération, abus volontaire, accident ou mauvais
usage du produit annulera cette garantie.
GLASS DOORS & BRASS PLATED PARTS . . .
Glass doors are not warranted for breakage due to misuse or ac-
cident.
Brass parts should be cleaned with lemon oil only. Brass cleaners
cannot be used. Mortar mix and masonry cleaners may corrode
the brass finish. The Company will not be responsible for, nor will it
warrant any brass parts which are damaged by external chemicals.
PORTES EN VERRE & PIECES PLAQUEES LAITON . . .
Les portes en verre ne sont pas garanties contre le bris causé par
un mauvais usage ou un accident.
Les pièces en laiton devraient être nettoyées qu'avec de l'essence
de citron. Les nettoyeurs de laiton ne peuvent pas être utilisés. La
Société ne sera pas responsable pour, et ne garantit pas les pièces
en laiton qui sont endommagées par de refoulement.
IF WARRANTY SERVICE IS NEEDED . . .
1) Contact your supplier. Make sure you have your warranty,
your sales receipt, and the model/serial number of your CFM
Specialty Home Products product.
SI UN SERVICE SOUS GARANTIE EST REQUIS . . .
1) Communiquez avec votre détaillant. Assurez-vous que vous
avez votre garantie, votre reçu de caisse ainsi que le numéro
de modèle/série de votre produit CFM Specialty Home Prod-
ucts.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
2) NE TENTEZ PAS D'EFFECTUER DES REPARATIONS VOUS-
MEME.
10007572
15
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
|